PT Outlet

Characteristics of the Product

  • Acquired KFI
  • Replaces existing TEE
  • All-in-one type of the existing TEE and screw socket

Merits of the Product

Economic Feasibility

  • Economical compared to the existing Tee and reduction of construction cost due to the reduction of welding volume
  • Reduction of work time and labor cost through simple construction
  • Reduction of material loss without pipe cutting

Safety

  • Reduction of leakage risk due to the reduction of welding volume compared to the existing Tee
  • Insufficient thickness of the pipe compared to Tee drawing and concerns about occurrence of stress cracks
  • Reduction of leakage risk due to the reduction of combining points

Standards

Performance Test Result

무제 문서

Test Item

Test Standard(KFI)

KFL

Pressure-Resistance Test

When applying 1.5 times of the maximum operating pressure, there should be no cracks, permanent deformation or damage.

3.0MPa

Body Strength Test

When applying 5 times pressure of the highest operating pressure (higher than 1.4MPa), there should be no cracks, permanent deformation or damage.

10MPa