Characteristics of the Product
- Acquired KFI
- A product that replaces combination of TEE, NIPPLE and REDUCER
- Reduction of combining areas
Merits of the Product
Economic Feasibility
- Reduction of material costs by replacing the welding and screwing combination
- Reduction of work time and labor cost through simple construction
- Reduction of material loss without pipe cutting
Safety
- Reduction of leakage and rupture risks with the reduction of combination of TEE, NIPPLE and REDUCER
- Reduction of leakage risk due to the reduction of welding volume
Standards
Performance Test Result
Test Item |
Test Standard(KFI) |
PLS |
KFI |
Pressure-Resistance Test |
When applying 1.5 times of the maximum operating pressure, there should be no cracks, permanent deformation or damage. |
2.1MPa | pass |
Body Strength Test |
When applying 5 times pressure of the highest operating pressure (higher than 1.4MPa), there should be no cracks, permanent deformation or damage. |
7MPa | pass |
Test Item |
Test Standard(UL)) |
PLS |
UL |
Leakage Test |
When applying twice pressure of the highest operating pressure (300 PSI), there should be no cracks, permanent deformation or damage. |
600 PSI(4.14MPa) | pass |
Pressure-Resistance Test |
When applying 4 times pressure of the highest operating pressure (300 PSI), there should be no cracks, permanent deformation or damage. |
1200 PSI (8.27MPa) | pass |
Body Strength Test |
When applying 5 times pressure of the highest operating pressure (300 PSI), there should be no cracks, permanent deformation or damage. |
1500 PSI (10.34MPa) | pass |